Environmental Sensors Logo   Contact Environmental Sensors
 
 
 

Ammonia Monitor Z-800XP

Z-800xp

 

Model Z-800XP
Ammonia Monitor

pdfDownload PDF

Theory of Operation

The sensing element of the instrument is an electrochemical cell. The cell is a four-electrode type, which contains a working and an active auxiliary electrode. The signal from the auxiliary electrode is used for temperature compensation and to improve the selectivity of the entire sensor. The sensor response is linear with the concentration of the target gas in air.

Interferences

Gas Concentration Meter Output

Alcohols

1000 ppm

0 ppm

Carbon Dioxide

5000 ppm

0 ppm

Carbon Monoxide

100 ppm

0 ppm

Hydrocarbons

% range

0 ppm

Hydrogen

10000 ppm

0 ppm

Hydrogen Sulfide

20 ppm

2 ppm

Features

  • Portable
  • Internal Pump
  • Rechargeable Battery
  • Remote Sampling
  • Simple to Use
  • TWA, STEL and Peak
  • Audible Adjustable Alarm
  • Data Logging

Description

Environmental Sensors Co.'s Ammonia Meter is a portable desktop instrument that measures ammonia concentration in a range of 0-100 ppm and a resolution of 0.1 ppm.

The instrument makes it possible to monitor ammonia vapor in air. The insturment has an LCD display giving concentrations in ppm every 10 seconds, a low battery indicator, and an audible alarm that can be set at any level from 0-100 ppm.

With the touch of a button, the meter displays STEL (average of every 15 min.), TWA (8 hour average) and Peak.

The internal pump makes it possible to sample from hard-to-reach areas or confined spaces by attaching a flexible tube to the meter.

Data Logging

The Z-800XP meter stores all of the exposure points for up to 5 logs (a log is created in the instrument's internal memory each time it is used). A log contains: date, time, number of exposure points, the interval between each point, and the actual exposure points. All of the log files can be easily uploaded to PC using components vailable within the Microsoft Windows Operation System or the termianl software included with the instrument.

 

Meter Spec

Sensor Type Electrochemical

Nominal Range

0-100 ppm

Maximum

200 ppm

Sensor Life

> 2 years

Resolution

0.1 ppm

Min. Detectable

0.1 ppm

Response Time

< 60 sec.

Warm-Up Time

60 sec.

Operating Temperature

-20 °C to 40 °C

Pressure Range

Atm ± 10%

Relative Humidity

15 - 90 % non-condensing

Alarm

Audible 80db

Dimensions

H x D x W: 7.5" x 5.75" x 2.75"

Weight

900 grams

Battery

Internal Rechargeable Battery or AC Adaptor

Warranty

One Year
© Copyright 2014 Environmental Sensors Co. All Rights Reserved